Ultrasonic control electric box is also called ultrasonic ultrasonic sonochemistry machine generator, ultrasonic signal is produced by the device, in many cases often will encounter all sorts of reasons caused by ultrasonic emulsification machine load current is too high. Ultrasonic current is big, the first thing to distinguish between the ultrasonic generator itself component damage caused by current is big, big or there is something wrong with the ultrasonic output load current. Very simple, remove the ultrasonic output line, no-load test of ultrasonic generator current, if the normal, it's said the ultrasonic vibration system failure.
Experience has shown that ultrasonic emulsification mechanical and electrical flow generally is due to the ultrasonic transducer ultrasonic vibration systems and ultrasonic generator does not match. Aiming at this problem, to check the every element of ultrasonic vibration system is normal, whether the link between the screw loosening, ultrasonic mould such as whether, cracks, etc.
Ultrasonic die head screw loosening between ultrasonic cutting machine transducer and lead to high current, generally has been in use for a period of time the machine method is to use ultrasonic die head special wrench tight it see if not lock die head.
Replace the ultrasonic transducer vibrator or the ultrasonic die, if you have to replace these two parts lead to high current after this belongs to the normal situation, as long as through ultrasonic frequency adjustment can solve this problem.
Ultrasonic mould or die head damaged or broken, generally used for a long time or long time appear in the use of ultrasonic, excluding method is to check whether there is crack, die appearance or install to other ultrasonic detection system.
Don't use more than one week, please and dustproof ultrasonic dispersion machine cover (plastic bag). When not in use for a long time, please put the machine appearance is wiped, oiling and maintenance, and cover the envelope attached to the machine, placed in a dry and ventilated place. Each welder use full month, sliding parts should be wiped clean, besmear again high quality lubricating oil. In addition to the lifting screw received lubricating oil, other parts do not need any agent. Should control box cover, a month with a clean with no moisture air gun, remove the dust in the cabinet, to keep the good parts.
Look if there is dirt, with a clean cloth to wipe, every six months the application of dry compressed air blasting machine, dust cleaning machine side plate, surface when it is forbidden to use all kinds of flux, should use neutral detergent, wipe gently. Welding head itself is in accordance with the welding material, and must cooperate with the resonance of the vibration system. Welding head and bottom die and work often kept clean. Wipe machinery on a regular basis, but do not use liquid cleaning, hair vibration box (recommendation: safekeeping) don't stress or place above the fluid.